Model | SYNK-7K-SG05LP1- SM2 | SYNK-7.6K-SG05LP1- SM2 | SYNK-8K-SG05LP1- SM2 |
Battery Input Date |
| ||
Battery Type | Lead-acid or Li-Ion | ||
Battery Voltage Range | 48Vd.c (40Vd.c ~ 60Vd.c) | ||
Max. Charging/Discharging Current | 175Ad.c (max.) | 190Ad.c (max.) | |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||
Number of Battery Input | 1 | ||
PV String Input Data |
|
| |
Max. PV Access Power | 14000W | 15200W | 16000W |
Max. PV Input Power | 11200W | 12160W | 12800W |
Max. PV Input Voltage | 500V | ||
Start-up Voltage | 125V | ||
PV Input Voltage Range | 125-500V | ||
MPPT Voltage Range | 150-425V | ||
Full Load MPPT Voltage Range | 200-425V | ||
Rated PV Input Voltage | 370V | ||
Max. Operating PV Input Current | 26A+26A | ||
Max. Input Short-Circuit Current | 34A+34A | ||
No. of MPP Trackers/No. of Strings MPP Tracker | 2/2+2 | ||
Max. Inverter Backfeed Current to The Array | 0 | ||
AC Input/Output Data |
| ||
Rated AC Input/Output Active Power | 7000W | 7600W | 8000W |
Max. AC Input/Output Apparent Power | 7700VA | 8360VA | 8800VA |
Peak Power (off-grid) | 2 times of rated power, 10s | ||
Rated AC Input/Output Current | 31.9/30.5Aa.c | 34.6/33.1Aa.c | 36.4/34.8Aa.c |
Max. AC Input/Output Current | 35/33.5Aa.c | 38/36.4Aa.c | 40/38.3Aa.c |
Max. Continuous AC Passthrough (grid to load) | 50A | ||
Max. Output Fault Current | 70A | 76A | 80A |
Max. Output Overcurrent Protection | 140A | ||
Rated Input/Output Voltage/Range | 220V/230V 0.85Un-1.1Un | ||
Grid Connection Form | L+N+PE | ||
Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | ||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||
Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||
DC Injection Current | <0.5% ln | ||
Efficiency |
| ||
Max. Efficiency | 97.60% | ||
Euro Efficiency | 96.50% | ||
MPPT Efficiency | >99% | ||
Protection |
|
Integrated | PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection. |
Surge Protection | DC Type II / AC Type II |
Over Voltage Category | DC Type II / AC Type III |
Interface |
|
Display | LCD+LED |
Communication Interface | RS232, RS485, CAN |
Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) |
General Data |
|
Operating Temperature Range | -40~60 ºC, >45 ºC Derating |
Permissible Ambient Humidity | 0-100% |
Permissible Altitude | 2000m |
Noise | <30 dB |
Ingress Protection (IP) Rating | IP65 |
Inverter Topology | Non-Isolated |
Over Voltage Category | OVC II(DC), OVC III(AC) |
Cabinet Size (WxHxD) | 366x589.5x237mm (Excluding connectors and brackets) |
Weight | 27.2kg |
Warranty | 5 years (10 years when installed with a Sunsynk battery) |
Type of Cooling | Smart cooling |
Grid Regulation | NRS 097-2-1; Additional connections available upon request |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |