Model | SYNK-5K-SG04LP1-SM2 |
Battery Input Date |
|
Battery Type | Lead-acid or Li-Ion |
Battery Voltage Range | 40Vd.c ~ 60Vd.c |
Max. Charging/Discharging Current | 120Ad.c |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS |
Number of Battery Input | 1 |
PV String Input Data |
|
Max. PV Access Power | 10000W |
Max. PV Input Power | 8000W |
Max. PV Input Voltage | 500V |
Start-up Voltage | 125V |
PV Input Voltage Range | 125~500V |
MPPT Voltage Range | 150~425V |
Full Load MPPT Voltage Range | 300~425V |
Rated PV Input Voltage | 370V |
Max. Operating PV Input Current | 18Ad.c + 18Ad.c |
Max. Input Short-Circuit Current | 27Ad.c + 27Ad.c |
No. of MPPT/No. of Strings per MPPT | 2/1+1 |
Max. Inverter Backfeed Current to the Array | 0 |
AC Input/Output Data |
|
Rated AC Input/Output Active Power | 5000W |
Max. AC Input/Output Apparent Power | 5500VA |
Peak Power (Off-Grid) | 2 times of rated power, 10 s |
Rated AC Input/Output Current | 22.8/21.8Aa.c |
Max. AC Input/Output Current | 25/24Aa.c |
Max. Continuous AC Passthrough (grid to load) | 35A |
Max. Output Fault Current | 50A |
Max. Output Overcurrent Protection | 80A |
Rated Input/Output Voltage/Range | 220 V/230 V 0.85Un-1.1Un |
Grid Connection Form | L+N+PE |
Rated Input/Output Grid Frequency/Range | 50 Hz/45 Hz-55 Hz 60 Hz/55 Hz-65 Hz |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
Total Current Harmonic Distortion THDi | <3% (of nominal power) |
DC Injection Current | <0.5% ln |
Efficiency |
|
Max. Efficiency | 97.60% |
Euro Efficiency | 96.50% |
MPPT Efficiency | >99% |
Protection |
|
Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Power Network Monitoring, Island Protection Monitoring, Earth Fault Detecion, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detecion |
Integrated (Optional) | Arc Fault Circuit Interrupter (AFCI) |
Surge Protection Level | TYPE II (DC), TYPE II (AC) |
Interface |
|
Display | LCD+LED |
Communication Interface | RS232/RS485/CAN |
Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) |
General Data |
|
Operating Temperature Range | -40~60ºC, >45ºC Derating |
Permissible Ambient Humidity | 0~100% |
Permissible Altitude | 2000m |
Noise | <30dB |
Ingress Protection (IP) Rating | IP65 |
Inverter Topology | Non-Isolated |
Over Voltage Category | OVC II (DC), OVC III (AC) |
Net Weight | 19kg |
Cabinet Size (WxHxD) | 376×470×241.5 mm (Excluding connectors and brackets) |
Warranty | 5 years (10 when installed with a Sunsynk battery) |
Type of Cooling | Natural Cooling |
Grid Regulation | NRS 097-2-1; Additional connections available upon request |
EMC/Safety Regulation | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
Pollution Degree | PD2 (Inside) PD3 (Outside) |
Manufacturer Country | China |
NOTICE Safe Transport and Handling of the Inverter When transporting the equipment, always use its original packaging and keep it intact as a complete unit. Store the product in a dry environment, avoiding direct sunlight, and maintain a temperature range between -40°C and 60°C. As the equipment can be quite heavy, always consider its total weight when moving, transporting, or installing it, ensuring that the installation site has adequate load-bearing capacity. Transporting and installing the inverter should only be carried out by qualified personnel. | |