Single Phase 3.6/5/6kW LV01 C1 Acure Datasheets

Created by Lee Dobson, Modified on Wed, 13 May at 9:15 PM by Lee Dobson

Model

SunC1-3.6LV01(W/B)

SunC1-5.0LV01(W/B)

SunC1-6.0LV01(W/B)

Battery Input Data

 

Battery Type

Lead-acid or Lithium-ion

Battery Voltage Range

40-60V

Max. Charging Current

90A

120A

135A

Max. Discharging Current

90A

120A

135A

Charging Strategy for Li-ion Battery

Self-adaption to BMS

Number of Battery Input

1

PV String Input Data

 

Max. PV Access Power

7200W

10000W

12000W

Max. PV Input Power

5760W

8000W

9600W

Max. PV Input Voltage

500V

Start-up Voltage

125V

MPPT Voltage Range

150-425V

Rated PV Input Voltage

370V

Max. Operating PV Input Current

18+18A

Max. Input Short-Circuit Current

27+27A

No. of MPP Trackers / No. of Strings MPP Tracker

2/1+1

AC Input/Output Data

 

Rated AC Input/Output Active Power

3600W

5000W

6000W

Max. AC Input/Output Apparent Power

3960VA

5500VA

6600VA

Rated AC Input/Output Current

16.4/15.7A

22.8/21.8A

27.3/26.1A

Max. AC Input/Output Current

18/17.3A

25/24A

30/28.7A

Max. Continuous AC Passthrough (Grid to Load)

35A

40A

Peak Power (Off-Grid)

2 times of rated power, 10s

Power Factor Adjustment Range

0.8 leading to 0.8 lagging

Rated Input/Output Voltage/Range

220/230V 0.85Un-1.1Un

Rated Input/Output Grid Frequency/Range

50/45-55Hz, 60/55-65Hz

Grid Connection Form

L+N+PE

Total Current Harmonic Distortion THDi

<3% (of nominal power)

DC Injection Current

<0.5% In

Efficiency

 

Max. Efficiency

97.6%

Euro Efficiency

96.5%

MPPT Efficiency

>99%

Protection

 

Integrated

DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal 

Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC 

Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current 

Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island 

Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level

Surge Protection Level

TYPE II(DC), TYPE II(AC)

Interface

 

Communication Interface

RS485/RS232/CAN

Monitor Mode

GPRS/WIFI/Bluetooth/4G/LAN(optional)

General Data

 

Operating Temperature Range

-40 to +60°C, >45°C Derating

Permissible Ambient Humidity

0-100%

Permissible Altitude

2000m

Noise

<30dB

Ingress Protection (IP) Rating

IP65

Inverter Topology

Non-Isolated

Over Voltage Category

OVC II(DC), OVC III(AC)

Cabinet Size (WxHxD)

376×530×276mm (Excluding Connectors and Brackets)

Weight

19.35kg

Type of Cooling

Natural Cooling

Warranty

5 years (10 years when installed with a Sunsynk battery)

Grid Regulation

G98/G99, NRS 097-2-1, EN 50549-1

Safety / EMC Standard

IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent