how to restart the system

Created by Paul Pablo Tregent, Modified on Thu, 13 Nov at 3:44 PM by Adrian Lois Moreno Dupont

We would recommend restarting the system as follows:

  1. Isolate the AC supply.

  2. Isolate the PV input.

  3. Press the silver button to turn the inverter off.

  4. Isolate the batteries.

  5. Wait 30 seconds.

  6. Turn the batteries back on.

  7. Press the silver button to turn the inverter back on.

  8. Wait 5–8 minutes for the Normal light to turn on.

  9. Once the Normal light is on, reintroduce the PV and AC.